|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
200W Single Output with PFC Function Features : HRP-200 series Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Built-in remote sense function 5 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) HRP-200-3.3 3.3V 40A 0 ~ 40A 132W 2.8 ~ 3.8V 2.0% 0.5% 1.5% 16ms/230VAC HRP-200-5 5V 35A 0 ~ 35A 175W 90mVp-p 4.3 ~ 5.8V 2.0% 0.5% 1.0% HRP-200-7.5 7.5V 26.7A 0 ~ 26.7A 200.3W 100mVp-p 6.8 ~ 9V 2.0% 0.5% 1.0% HRP-200-12 12V 16.7A 0 ~ 16.7A 200.4W 120mVp-p 10.2 ~ 13.8V 1.0% 0.3% 0.5% HRP-200-15 15V 13.4A 0 ~ 13.4A 201W 150mVp-p 13.5 ~ 18V 1.0% 0.3% 0.5% HRP-200-24 24V 8.4A 0 ~ 8.4A 201.6W 150mVp-p 21.6 ~ 28.8V 1.0% 0.2% 0.5% HRP-200-36 36V 5.7A 0 ~ 5.7A 205.2W 250mVp-p 28.8 ~ 39.6V 1.0% 0.2% 0.5% HRP-200-48 48V 4.3A 0 ~ 4.3A 206.4W 250mVp-p 40.8 ~ 55.2V 1.0% 0.2% 0.5% RIPPLE & NOISE (max.) Note.2 80mVp-p 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load 16ms/115VAC at full load 120 ~ 370VDC PF>0.99/115VAC at full load 86% 88% 88% 88% 89% 89% 1.1A/230VAC 70A/230VAC Note.5 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. PF>0.95/230VAC 80% 2.2A/115VAC 35A/115VAC <1.2mA / 240VAC 84% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 95 105 5 5 (TSW1) detect on heatsink of power transistor (TSW2) detect on main power output choke 57.6 ~ 67.2V Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -30 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A 209.4K hrs min. MIL-HDBK-217F (25 ) 199*98*38mm (L*W*H) 0.77Kg; 18pcs/14.9Kg/0.81CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-200-SPEC 2010-05-12 200W Single Output with PFC Function Mechanical Specification 197 HRP-200 Case No.902E series Unit:mm 9 1 9.5 2 3 85.5 4 5 8.2 3.5 80 7 6 7 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Assignment Pin No. DC OUTPUT -V 4,5 DC OUTPUT +V 6,7 3.5 LED CN100 SVR1 57.5 4- M 3 4.5 120 199 6.5 9 Pin No. Assignment NC 1 2 NC 3 NC 4 NC +S 5 -S 6 Mating Housing Terminal 3. 5 18.5 9.5 Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DS or equivalent 190 3.5 28.5 HRS DF11-6DS HRS DF11-**SC or equivalent or equivalent 13max. 28 150.75 3M3 Block Diagram ACTIVE INRUSH CURRENT LIMITING +S RECTIFIERS & PFC O.T.P. FG PFC CONTROL PWM CONTROL POWER SWITCHING O.L.P. RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. +V -V -S 18 fosc :70KHz I/P EMI FILTER Derating Curve Output Derating VS Input Voltage Ta = 25 125 100 100 90 80 80 70 60 LOAD (%) 40 LOAD(%) 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 125 135 155 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:HRP-200-SPEC 2010-05-12 38 98 15 26 |
Price & Availability of HRP-200-33 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |